When the static voltage exceeds 150V, the system triggers audio and visual alarms. The contact ball is made from semi-conductive electrostatic material with a surface resistivity of 10⁷–10⁹ Ω, ensuring a safe, slow discharge process without generating any sparks.
PS-Y Model (Barrier Version) – Gate-Level Static Discharge Control
The PS-Y version is installed at facility entry points. With its rail-type design, it ensures that every individual entering the site passes through and discharges static electricity completely before entering the sensitive workspace.
KEY PERFORMANCE FEATURES
- Contact ball made from static-conductive material, safe discharge with no sparks.
- Mechanical unlocking system, purely physical, stable, and secure to operate.
- Barrier design structure, ensures mandatory static discharge upon entry.
- Body voltage detection with alerts when values exceed 150V.
- Built-in ground loop monitoring, alarm activates when grounding is disconnected.
- Ultra-low power consumption, runs reliably without battery replacement under standard conditions.
CERTIFICATIONS & TEST REPORTS
- Explosion-proof certificate and safety test reports
- 3C Certification (China Compulsory Certification)
- National patent – No: ZL 2010 1 0112731.7
- Discharge transfer test report: < 0.1uC
- Corrosion resistance & protection level inspection report